Earthwise Single Hung Windows Installed

These single hung windows are a traditional style that opens by raising the bottom sash. The top glass in single hung windows is fixed in place.

  • Fixed meeting rail provides superior structural stability
  • Easy installation due to fewer moving parts
  • Earthwise single hung windows provide excellent performance and energy efficiency with our insulated glass system, Sunshield vinyl technology and premium weatherstripping

 

 

 

 


IMPACT WINDOWS

 

TEXAS DEPARTMENT OF INSURANCE (Impact Window)

Engineering Services Program / MC 103-3A 333 Guadalupe Street Phone No. (512) 322-2212 Fax No. (512) 463-6693

PRODUCT EVALUATION

WIN-1835

P.O. Box 149104 Austin, Texas 78714-9104

Effective Date: November 1, 2013 Reevaluation Date: September 2015

The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building Code (IBC).

This product evaluation is not an endorsement of this product or a recommendation that this product be used. The Texas Department of Insurance has not authorized the use of any information contained in the product evaluation for advertising, or other commercial or promotional purpose.

This product evaluation is intended for use by those individuals who are following the design wind load criteria in Chapter 3 of the IRCandSection1609oftheIBC. Thedesignloadsdeterminedforthebuildingorstructureshallnotexceedthedesignload ratingspecifiedfortheproductsshowninthelimitationssectionofthisproductevaluation. Thisproductevaluationdoesnot relieve a Texas licensed engineer of his responsibilities as outlined in the Texas Insurance Code, the Texas Administrative Code, and the Texas Engineering Practice Act.

142.094SH-003/143/143.095/145.095 Vinyl Single Hung Windows, New and Replacement Construction, Impact Resistant, by

Earthwise Group, LLC, manufacturer by Showcase Custom Windows and Doors 1702 Cullen Blvd.
Houston, Texas 77023

Telephone: (713) 926-8500 General Description:

System

Description

Label Rating

Design Pressure Rating

1

143.095 Oriel
Vinyl Single Hung Windows – New Construction

R-PG65 44 x 84-H Missile Level D

 65 psf

2

142.094SH-003/143/145.095 Vinyl Single Hung Windows – New Construction

H-R50 48 x 72 Missile Level D

 50 psf

3

142.094SH-003/143/145.095 Vinyl Single Hung Windows – Replacement Construction

H-R50 53 x 72 Missile Level D

 50 psf

Product Dimensions:

System

Overall Size

Operating Sash

Fixed Daylight Opening

1

44.00” x 84.00”

40.88” x 35.13”

39.19” x 44.75”

2

48.00” x 72.00”

44.25” x 35.00”

43.00” x 32.63”

3

53.13” x 72.00”

50.50” x 35.50”

48.13” x 32.63”

1 of 3

November 1, 2013 WIN-1835 (cont.)

Product Identification (Certification Agency Labels on Window): NOTE: There are two labels on each window

System

Certification Agency

Keystone

Manufacturer’s Name or Code Name

CAR No. 839-1060.0 CAR No. 839-216

1

Product Name

143.095 SH Oriel Impact Single Hung

Test Standards

AAMA/WDMA/CSA 101/I.S.2/A440-08 ASTM E 1886-05; ASTM E 1996-06; Missile Level D

Certification Agency

Keystone

Manufacturer’s Name or Code Name

CAR No. 839-1035.0 CAR No. 839-212

2

Product Name

142.094SH-003/143/145.095 NC Imp Single Hung

Test Standards

AAMA/WDMA/CSA 101/I.S.2/A440-05 ASTM E 1886-05; ASTM E 1996-06; Missile Level D

Certification Agency

Keystone

Manufacturer’s Name or Code Name

CAR No. 839-1034.0 CAR No. 839-211

3

Product Name

142.095SH-003/143/145.095 Rep Imp Single Hung

Test Standards

AAMA/WDMA/CSA 101/I.S.2/A440-05 ASTM E 1886-05; ASTM E 1996-06; Missile Level D

Impact Resistance:

Installation:

Impact Resistant

Requirement

Yes

These products satisfy the Texas Department of Insurance’s criteria for protection from windborne debris in the Inland I and Seaward zone. The assemblies may be installed at any height on the structure as long as the design pressure rating for the assemblies is not exceeded

System

Type of Installation

New Construction – Nailing Fin

Wall Framing

Spruce-Pine-Fir

1

Fasteners

Minimum 6D nails (0.113” diameter smooth shank)

Fastener Location/Spacing

Located approximately 6 inches from each corner and approximately 12 inches on center along the perimeter

Fastener Penetration

Minimum of 1 12 inches into the wall framing members

Type of Installation

New Construction – Nailing Fin

Wall Framing

Spruce-Pine-Fir

2

Fasteners

Minimum No. 8 Screws

Fastener Location/Spacing

Located approximately 2 inches from each corner and approximately 10 inches on center along the perimeter

Fastener Penetration

Minimum of 1 12 inches into the wall framing members

Texas Department of Insurance

 

November 1, 2013 WIN-1835 (cont.)

Installation (Continued):

System

Type of Installation

Replacement Construction – Frame

Wall Framing

Spruce-Pine-Fir

Fasteners

Minimum No. 8 Screws

3

Fastener Location/Spacing

Along each side jamb, located approximately 2 inches from each corner and approximately 16 inches on center along the perimeter.
No fasteners along the head and the sill.

Fastener Penetration

Minimum of 1 12 inches into the wall framing members

Note: The manufacturer’s installation instructions shall be available on the job site during installation. All fasteners shall be corrosion resistant as specified in the International Residential Code (IRC), the International Building Code (IBC), and the Texas Revisions.

Non-Impact

TEXAS DEPARTMENT OF INSURANCE
Engineering Services Program / MC 103-3A 333 Guadalupe Street Phone No. (512) 322-2212 Fax No. (512) 463-6693
PRODUCT EVALUATION
WIN-1836
P.O. Box 149104 Austin, Texas 78714-9104
Effective Date: November 1, 2013 Reevaluation Date: March 2016
The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building Code (IBC).
This product evaluation is not an endorsement of this product or a recommendation that this product be used. The Texas Department of Insurance has not authorized the use of any information contained in the product evaluation for advertising, or other commercial or promotional purpose.
This product evaluation is intended for use by those individuals who are following the design wind load criteria in Chapter 3 of the IRCandSection1609oftheIBC. Thedesignloadsdeterminedforthebuildingorstructureshallnotexceedthedesignload ratingspecifiedfortheproductsshowninthelimitationssectionofthisproductevaluation. Thisproductevaluationdoesnot relieve a Texas licensed engineer of his responsibilities as outlined in the Texas Insurance Code, the Texas Administrative Code, and the Texas Engineering Practice Act.
142.094SH-003/143/145.095 Vinyl Single Hung Windows, New and Replacement Construction, Non- Impact Resistant, manufactured by
Earthwise Group, LLC, manufactured by Showcase Custom Windows and Doors 1702 Cullen Blvd.
Houston, Texas 77023
Telephone: (713) 926-8500 General Description:
Product Dimensions:
Product Identification (Certification Agency Label on Window):

System
Description

Label Rating

Design Pressure Rating
1
142.094SH-003/143/145.095 Vinyl Single Hung Windows – New Construction
H-R50 48 x 72
 50 psf
2

142.094SH-003/143/145.095 Vinyl Single Hung Windows – Replacement Construction

H-R50 53 x 72

 50 psf

System
Overall Size

Operating Sash
Fixed Daylight Opening
1
48.00” x 72.00”

44.25” x 35.00”
43.00” x 32.63”
2

53.13” x 72.00

50.50” x 35.50”

48.13” x 32.63”

System

Certification Agency
Keystone

1
Manufacturer’s Name or Code Name
CAR No. 839-1038

Product Name
142.094SH-003/143/145.095 NC Single Hung

Test Standards
AAMA/WDMA/CSA 101/I.S.2/A440-05

Certification Agency
Keystone

2
Manufacturer’s Name or Code Name
CAR No. 839-1037

Product Name
142.094SH-003/143/145.095 Rep Single Hung

Test Standards
AAMA/WDMA/CSA 101/I.S.2/A440-05

1 of 2
November 1, 2013 WIN-1836 (cont.)
Impact Resistance:
Installation

Impact Resistant

Requirement
No
Impact protective system required when product is installed in areas where windborne debris protection is required
System

Type of Installation
New Construction – Nailing Fin

Wall Framing
Spruce-Pine-Fir

1
Fasteners
Minimum No. 8 Screws

Fastener Location/Spacing
Located approximately 2 inches from each corner and approximately 10 inches on center along the perimeter

Fastener Penetration
Minimum of 1 12 inches into the wall framing members

Type of Installation
Replacement Construction – Frame

Wall Framing
Spruce-Pine-Fir

Fasteners
Minimum No. 8 Screws

2
Fastener Location/Spacing
Along each side jamb, located approximately 2 inches from each corner and approximately 16 inches on center along the perimeter.
No fasteners along the head and the sill.

Fastener Penetration
Minimum of 1 12 inches into the wall framing members

Note: The manufacturer’s installation instructions shall be available on the job site during installation. All fasteners shall be corrosion resistant as specified in the International Residential Code (IRC), the International Building Code (IBC), and the Texas Revisions.